Fluid path - connectors

BioBarb

Overview

BioBarb™ - Hose tail to Tri-Clamp adaptors

BioBarb hose tail to Tri-Clamp adaptors are produced from DMF listed polypropylene compliant with FDA and USP Class VI and European Pharmacopoeia.

Available as ½ - ¾" mini and 1 – 1 ½" standard options

Features and benefits

  • Lot numbers moulded in for full traceability
  • Full through bore diameter ensures a smooth transition with no obstructions
  • Identical internal diameter of barb and tubing allows drainage along an unimpeded flow path
  • Enhanced Tri-Clamp design reduces the risk of a seal failure
  • Suitable for sterilisation by autoclave and gamma irradiation
  • Precision compression between tube and fitting eliminates flow by-pass and media entrapment

Technical summary

Max. operating pressure 4 bar
Max. operating pressure 58 psi
Shelf life 5 years
Certification ADCF, ISO 14644-1 Class 7, ISO 9001, ISO10993, USP Class VI
Size 1 HB, 1/2 HB, 1/4 HB, 1/8 HB, 3/4 HB, 3/8 HB, 5/8 HB, 7/8 HB in
TC Size ½-¾ TC - 1-1½ TC in

Technical Summary table lists features available within the range. See ‘Specifications’ tab for model specific information.

Specifications

Technical specifications

BioBarb
Max. operating pressure 4 bar
Max. operating pressure 58 psi
Fluid temperature range 5 to 40 °C
Fluid temperature range 40 to 104 °F
Operating temperature range -5 to 40 °C
Operating temperature range 23 to 104 °F
Autoclave stability 121 °C 30 minutes
Gamma stability 50 kGy
Shelf life 5 years
Certification ADCF, ISO 14644-1 Class 7, ISO 9001, ISO10993, USP Class VI
Size 1 HB, 1/2 HB, 1/4 HB, 1/8 HB, 3/4 HB, 3/8 HB, 5/8 HB, 7/8 HB in
TC Size ½-¾ TC - 1-1½ TC in
Quantity 10 PCS

Materials of construction

Material Natural PP

Validation

About the BioPure components validation guides

These components are manufactured and packed in an ISO 14644-1 Class 7 cleanroom from a DMF listed polypropylene compliant with FDA and USP VI. Product validation studies were performed on the post gamma irradiated BioPure components.

  • Evaluated for extractables using a multi-solvent approach to BPOG guidelines
  • USP Class VI compliant and Animal Derived Component Free (ACDF)
  • Raw material assigned FDA drug master number: DMF 9040 and fulfils requirements of European pharmacopoeia, 5th edition (2004) and supplement 5.8 (07/2007), monograph 3.2.2.
  • Suitable for sterilisation by autoclave and gamma irradiation
  • Lot traceability
  • Precision compression between tube and fittings eliminates flow bypass and media entrapment

Validation summary guide

The summary guide summarises the validation/qualification testing that has been carried out on BioPure components

View BioPure components summary guide - 379.5kb

Request full validation guide

Disclaimer: You hereby agree the provided validation guide is for private use only to assist in the qualification of the products listed within the validation guide.

You also agree that you will not copy, redistribute, transmit, assign, sell, broadcast, rent, share, lend, modify, adapt, edit or transfer the validation guide to any other party without prior consent from WMFTS.

Literature

Brochures

  1. BioPure overview (EN).pdf
    PDF - 863.8kb
  2. Bioprocessing (EN).pdf
    PDF - 3.5mb

Datasheet

    Other Resources

    1. ½ inch - ¾ inch TC to ⅛ inch bore BioBarb technical drawing.pdf
      PDF - 1.1mb
    2. 1½ inch TC to ⅞ inch bore BioBarb technical drawing.pdf
      PDF - 1.3mb
    3. 1½英寸TC½英寸孔BioBarb技术港湾式停车站g.pdf
      PDF - 1.2mb
    4. 1½ inch TC to 1 inch bore BioBarb technical drawing.pdf
      PDF - 1.5mb
    5. 1½ inch TC to ⅜ inch bore BioBarb technical drawing.pdf
      PDF - 1.2mb
    6. 1½ inch TC to ⅝ inch bore BioBarb technical drawing.pdf
      PDF - 1.3mb
    7. ½ inch - ¾ inch TC to ⅝ inch bore BioBarb technical drawing.pdf
      PDF - 1.1mb
    8. 1½ inch TC to ⅛ inch bore BioBarb technical drawing.pdf
      PDF - 1.2mb
    9. ½ inch - ¾ inch TC to ⅜ inch bore BioBarb technical drawing.pdf
      PDF - 1.1mb
    10. ½ inch - ¾ inch TC to ½ inch bore BioBarb technical drawing.pdf
      PDF - 1.1mb
    11. ½ inch - ¾ inch TC to ¼ inch bore BioBarb technical drawing.pdf
      PDF - 1.1mb
    12. 1½ inch TC to ¼ inch bore BioBarb technical drawing.pdf
      PDF - 1.2mb
    13. 1½ inch TC to ¾ inch bore BioBarb technical drawing.pdf
      PDF - 1.3mb

    Order Information

    Product codes

    BioBarb product codes

    Part Number Description TC Size Bore Size To Suit Tubing ID
    PPSTC0125BB 1 1/2" TC to 1/8" Bore 1" - 1 1/2" 1/8" 1/8" - 1/4" 3.2 mm - 6.4 mm
    PPSTC0250BB 1 1/2" TC to 1/4" Bore 1" - 1 1/2" 1/4" 1/4" - 3/8" 6.4 mm - 9.6 mm
    PPSTC0375BB 1 1/2" TC to 3/8" Bore 1" - 1 1/2" 3/8" 3/8" - 1/2" 9.6 mm - 12.7 mm
    PPSTC0500BB 1 1/2" TC to 1/2" Bore 1" - 1 1/2" 1/2" 1/2" - 5/8" 12.7 mm - 15.9 mm
    PPSTC0625BB 1 1/2" TC to 5/8" Bore 1" - 1 1/2" 5/8" 5/8" - 3/4" 15.9 mm - 19 mm
    PPSTC0750BB 1 1/2" TC to 3/4" Bore 1" - 1 1/2" 3/4" 3/4" - 7/8" 19mm - 22.2mm
    PPSTC0875BB 1 1/2" TC to 7/8" Bore 1" - 1 1/2" 7/8" 7/8" - 1" 22.2 mm - 25.4 mm
    PPSTC1000BB 1 1/2" TC to 1" Bore 1" - 1 1/2" 1" 1" 25.4mm
    PPMTC0125BB 1/2" - 3/4" TC to 1/8" Bore 1/2" - 3/4" 1/8" 1/8" - 1/4" 3.2 mm - 6.4 mm
    PPMTC0250BB 1/2" - 3/4" TC to 1/4" Bore 1/2" - 3/4" 1/4" 1/4" - 3/8" 6.4 mm - 9.6 mm
    PPMTC0375BB 1/2" - 3/4" TC to 3/8" Bore 1/2" - 3/4" 3/8" 3/8" - 1/2" 9.6 mm - 12.7 mm
    PPMTC0500BB 1/2" - 3/4" TC to 1/2" Bore 1/2" - 3/4" 1/2" 1/2" - 5/8" 12.7 mm - 15.9 mm
    PPMTC0625BB 1/2" - 3/4" TC to 5/8" Bore 1/2" - 3/4" 5/8" 5/8" 15.9 mm - 19 mm

    Recommended Products

    1. Pumpsil tubing

      Pumpsil tubing

      Platinum-cured silicone tubing with ultra smooth bore and excellent flow stability. -20 ºC to 80 ºC (-4 ºF to 176 ºF).

      Tubing - peristaltic

    2. PureWeld XL tubing

      PureWeld XL tubing

      High performance TPE tubing with exceptional life and accurate flow rates. Weldable and sealable for sterile connectivity.

      Tubing - peristaltic

    Related Products

    1. BioClamp® - Plastic Tri-Clamp

      BioClamp® - Plastic Tri-Clamp

      Manufactured from borosilicate reinforced nylon. Tamper evident feature available on the 1/2" to 4"

      Fluid path - connectors

    Our specialists are here to help you succeed.

    To order a product or ask a question

    Contact our experts