Chemical compatibility guide

    It is recommended that compatibility testing is always carried out to ensure the suitability of our products with your process chemical fluid. Actual chemical content can differ between suppliers and brands.

    ReNu and CWT pumphead wetted components for Qdos

    This guide details chemical compatibility between the process fluid and the wetted components within the pumphead only. The guide is not an indication of the suitability of the pump for your process. It does not indicate chemical compatibility of the components within the pumphead after failure. A full risk assesment should be carried out for all applications when pumping aggressive chemicals. Materials of manufacture can be found in the product datasheet. Please contact Watson-Marlow for further advice.

    The ReNu and CWT pumphead contains lubricant. It is the user’s responsibility to comply with local health and safety regulations, including ensuring chemical compatibility between the lubricant and the duty fluid before use.

    The Qdos pump should not be used in an ATEX environment, Hazardous environment or an environment that requires explosion proof certification.

    *在某些情况下,pumphea之间的兼容性d and the chemical is particularly dependant on a number of factors including chemical source and temperature. In these cases, trials are recommended to ascertain suitability.

    ReNu Santoprene label


    7bar (100psi) Max

    0M3.2200.PFP: ReNu 30 Santoprene pumphead
    0M3.3200.PFP: ReNu 60 Santoprene pumphead
    4bar (60psi) Max
    0M3.4200.PFP: ReNu 120 Santoprene pumphead

    ReNu SEBS label


    7bar (100psi) Max

    0M3.1800.PFP: ReNu 20 SEBS pumphead
    4bar (60psi)
    0M3.3800.PFP: ReNu 60 SEBS pumphead
    4bar (60psi) Max
    0M3.2800.PFP: ReNu 30 SEBS pumphead

    ReNu PU label


    4bar (60psi) Max

    0M3.1500.PFP: ReNu 20 PU pumphead

    A

    Available data indicates that the process chemical is compatible with the pumphead wetted components.

    B

    The process chemical is not fully compatible with the pumphead wetted components. Flow rate and pumphead life may be adverseley affected.

    C

    Not suitable for use with duty fluid. The process chemical is not compatible with some or all of the components. It may be unsafe to use the pumphead in this application.

    -

    Compatibility not confirmed. Compatability data with the chemical does not exist or has not been confirmed. Please contact Watson-Marlow for further details.

    Peristaltic tubing and hose elements

    Always make an immersion test before choosing a tube material for critical applications. Immerse a short length of the tubing (always available from Watson-Marlow Fluid Technology or its distributors) in a closed container of the fluid for 48 hours, and then examine it for signs of attack, swelling, embrittlement or other deterioration.

    A

    Tubing: 0-5% volume swell

    B

    Tubing: 5-10% volume swell

    C

    Tubing: 10% or greater volume swell

    -

    Not confirmed (no data)

    *The information contained in the chemical compatibility guide is believed to be correct. Watson-Marlow Fluid Technology Group accepts no liability for any errors it contains. It is the users responsibility to ensure chemical compatibility within their application.

    Duty fluid or chemical